AC Input,Process Indicator,Model DIS972,Wilkerson Instrument

AC Input Process Indicator Model DIS972


CONNECTIONS

Output - (Optional)
Output + (Optional)
NC
Input +
Input -
Shield
Alarm 1 NC (Optional)
Alarm 1 C (Optional)
Alarm 1 NO (Optional)
Alarm 2 NC (Optional)
Alarm 2 C (Optional)
Alarm 2 NO (Optional)
Power AC L1
Power AC L2
(Terminal Labeled)

1
2
3
4
5
6
7
8
9
10
11
12
13
14

AC Input,Process Indicator,Model DIS972,Wilkerson Instrument

AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Catalogue
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Manual


AC Input,Process Indicator,Model DIS972,Wilkerson Instrument


Features

AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Provides 4 1/2 Digit Display, Red or Green LEDs
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Display Calibrated in Engineering Units (V, mA, %, etc.)
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Proportional to AC Input
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Fully Isolated Output and/or 0, 1, or 2 Alarms (Optional)
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Alarm Setpoints Adjustable Without Disturbing Transmitter Output
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Fail-safe Alarm Operation
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument LED Alarm Status Indicator
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Adjustable Deadband
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument 50 mV or 1 mA Minimum Input Span
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Unlimited* Choice of Input/Output Ranges
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Fits Standard 1/8 DIN Cutout
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument Rated NEMA-4X, Splashproof and Corrosion Resistant When Properly Installed
AC Input,Process Indicator,Model DIS972,Wilkerson Instrument 5 + 5 Year Warranty


Description

The DIS972 provides a display, optional isolated DC output voltage or current proportional to an AC input signal, and optional alarm setpoints. The units include filtering and conditioning to reduce susceptibility to transients and noisy operations. The digital display utilizes an auto-zero dual-slope integrating A/D converter for accuracy and stability.  All controls are accessible by removing a gasketed front access panel. The display controls are wide-ranging so that they can be calibrated to display engineering units. Decimal point selection is made with a switch, also accessible from the front.

A complete set of engineering unit labels is sent with each DIS.  Once the display has been adjusted to read the correct engineering units, the alarm setpoints can be adjusted without test equipment and without disturbing the output voltage or current.

Either setpoint may be displayed by use of the SP CAL switch.  Each setpoint has an LED to indicate alarm status. The alarms have adjustable deadbands. Terminations are made to a screw terminal connector on the rear of the case.

Typical Applications

AC process indication, control, monitoring of electrical devices such as motors, pumps or heaters, etc.

Mounting

The DIS is designed to be mounted from the front of a panel through a standard horizontal 3.62 x 1.77 inches (1/8 DIN) cutout. Two mounting cam-screws secure the DIS to the panel.

Specifications

INPUT RANGE
Voltage
  select any range from 0 to 250 V rms max
    (min span 50 mV)

Current
  select any range between 0 to 5 A rms
    (min span 1 mA, internal shunt)

INPUT IMPEDANCE
Voltage
  200 kilohms

Current

Input
100µA
1 mA
10 mA
100 mA
1 A
5 A
Shunt Value
1000 OHM
100 OHM
10 OHM
1 OHM
0.1 OHM
0.01 OHM

OUTPUT RANGE
Voltage
  select any range between ±10 V
    10 mA max load
    (min span 0.2 V)
Current
  select any range from 0 to 20 mA max
    24 V compliance**
    (min span 1 mA)

RELAY CONTACTS (spdt)
Resistive Load:
  5 A max, 150 W max,
  240 VAC max, 30 VDC max
Inductive Load:
  1/8 HP max at 120/240 VAC

SETPOINT
each alarm 0 to 100% of span

DEADBAND
0.25% to 100% of span

RESPONSE TIME
1 sec typical

ISOLATION
Output/Input
  >500 megohms
Breakdown Voltage
  >600 VAC rms

DISPLAY
Digit Size
  .56 inch LED, 4 1/2 digits, ±19999

Decimal Point
  ±1.9.9.9.9

Control Range
  Zero
    ±19999
  Span
    min span 10
    max span 20000

Display Update
  3/sec

ACCURACY
±0.1% of span

LINEARITY
Display
  ±0.01% of span

Output
  ±0.025% of span

OUTPUT RIPPLE
<0.1% of span
  (peak to peak)

COMMON MODE REJECTION
120 dB, DC to 60 Hz

OPERATING TEMPERATURE
 14°F to 140°F
-10°C to 60°C

TEMPERATURE STABILITY
±(0.02% of span +30 µV)/°C max

POWER
115 VAC ±10%, 50/60 Hz
  (4 W max)
230 VAC ±10%, 50/60 Hz
  (4 W max)

 

 


* Within specified range limits.

** Compliance:  The sum of the voltage drops in the output loop cannot exceed 24 V at rated current 
    (1200 ohms at 20 mA).